RM12/ILP-3F4-E250 Datasheet

RM12/ILP-3F4-E250 Datasheet
Total Pages: 2
Size: 76.47 KB
Ferroxcube
RM12/ILP-3F4-E250 Datasheet Page 1
RM12/ILP-3F4-E250 Datasheet Page 2
RM12/ILP-3F4-E250

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F4

Diameter

-

Inductance Factor (Al)

250nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

56

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F4-A630

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F4

Diameter

-

Inductance Factor (Al)

630nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

140

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F4-A400

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F4

Diameter

-

Inductance Factor (Al)

400nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

90

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F36-E250

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F36

Diameter

-

Inductance Factor (Al)

250nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

56

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F4

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F4

Diameter

-

Inductance Factor (Al)

-

Tolerance

±25%

Gap

Ungapped

Effective Permeability (µe)

-

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.28

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

16.80mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F36-A630

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F36

Diameter

-

Inductance Factor (Al)

630nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

140

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F36-A400

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F36

Diameter

-

Inductance Factor (Al)

400nH

Tolerance

±3%

Gap

Gapped

Effective Permeability (µe)

90

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.388

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

24.50mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3F36

Ferroxcube

Manufacturer

Ferroxcube

Series

*

Core Type

RM

Supplier Device Package

RM 12

Material

3F36

Diameter

-

Inductance Factor (Al)

-

Tolerance

±25%

Gap

Ungapped

Effective Permeability (µe)

-

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

0.28

Effective Length (le) mm

42

Effective Area (Ae) mm²

148

Minimum Core Cross Section (Amin) mm²

125

Effective Magnetic Volume (Ve) mm³

6200

Finish

Uncoated

Height

16.80mm

Length

37.40mm

Width

16.10mm

RM12/ILP-3C95

Ferroxcube

Manufacturer

Ferroxcube

Series

-

Core Type

RM

Supplier Device Package

RM 12

Material

3C95

Diameter

-

Inductance Factor (Al)

-

Tolerance

-

Gap

-

Effective Permeability (µe)

-

Initial Permeability (µi)

-

Core Factor (ΣI/A) mm1

-

Effective Length (le) mm

-

Effective Area (Ae) mm²

-

Minimum Core Cross Section (Amin) mm²

-

Effective Magnetic Volume (Ve) mm³

-

Finish

Uncoated

Height

16.80mm

Length

37.40mm

Width

16.10mm

CLI-RM12/ILP

Ferroxcube

Manufacturer

Ferroxcube

Series

-

Accessory Type

Clamp

For Use With/Related Products

RM

Supplier Device Package

RM 12