Honeywell Sensing and Productivity Solutions Current Sensors
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Show Filters
Reset Filters
Apply Filters
CategorySensors / Current Sensors / Current Sensors
ManufacturerHoneywell Sensing and Productivity Solutions
Records 114
Page 1/4
Image |
Part Number |
Manufacturer |
Description |
In Stock |
Quantity |
Series | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Polarization | Mounting Type | Package / Case | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT SWITCH 1A AC/DC |
7,344 |
|
CSDA | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | Bidirectional | Connector | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT MR 56A AC/DC |
1 |
|
CSN | AC/DC | Magnetoresistive, Open Loop | 56A | 1 | Ratiometric, Current | - | - | - | ±0.24% | 4.75V ~ 5.25V | 0.2µs | 12mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 36A AC/DC |
8,460 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 45A AC/DC |
17,772 |
|
CSLH | AC/DC | Hall Effect, Open Loop | 45A | 1 | Ratiometric, Voltage | 18.5mV/N | - | - | - | 4.5V ~ 10.5V | 3µs | 11mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT SWITCH 1A AC/DC |
8,478 |
|
CSDA | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 57A AC/DC |
6,408 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 57A | 1 | Ratiometric, Voltage | 49.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 180A AC/DC |
7,080 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 180A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±15V | 0.5µs | 10mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 75A AC/DC |
6,354 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 39.4mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 72A AC/DC |
4,860 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 72A | 1 | Ratiometric, Voltage | 32.7mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 150A AC/DC |
7,812 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 16.2mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 225A AC/DC |
7,578 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 225A | 1 | Ratiometric, Voltage | 13.2mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 70A AC/DC |
6,240 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 70A | 1 | Ratiometric, Voltage | - | DC ~ 150kHz | ±1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 125A AC/DC |
8,928 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 125A | 1 | Ratiometric, Voltage | 19.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
8,190 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 100A AC/DC |
5,634 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 50A AC/DC |
4,968 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 125A AC/DC |
7,578 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 125A | 1 | Ratiometric, Voltage | 19.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 100A AC/DC |
6,708 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 29.7mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 100A AC/DC |
7,164 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 29.7mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 150A AC/DC |
5,454 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 19.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 125A AC/DC |
6,204 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 125A | 1 | Ratiometric, Voltage | 19.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 92A AC/DC |
7,560 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 92A | 1 | Ratiometric, Voltage | 25.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 150A AC/DC |
4,716 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 36A AC/DC |
4,014 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 225A AC/DC |
5,382 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 225A | 1 | Ratiometric, Voltage | 8.7mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 550A AC/DC |
7,110 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 550A | 1 | Ratiometric, Voltage | 4.3mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 400A AC/DC |
8,640 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | 5.8mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 310A AC/DC |
7,866 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 310A | 1 | Ratiometric, Voltage | 7.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 57A AC/DC |
8,820 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 57A | 1 | Ratiometric, Voltage | 49.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 62A AC/DC |
8,928 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 62A | 1 | Ratiometric, Voltage | 26.1mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |